EasyManuals Logo

Elstat ems25+ User Manual

Default Icon
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
77
www.elstat.io
10.25 light delay (Ld)
The table below details the lights delay (Ld) parameter
DISPLAY
DESCRIPTION
Defines the delay to switch off the cooler lights after the ems controller switches to the
saving mode
CONSIDERATOINS Must be set in multiples of 30
RANGE 0 to 120 minutes
GLOBAL DEFAULT 00 (no delay)
10.26 learning period (LP)
The table below details the learning period (LP) parameter
DISPLAY
DESCRIPTION Defines whether the ems controller uses a 1-day or a 7-day learning period.
CONSIDERATOINS None
RANGE 00 (1 day) or 01 (7 days)
GLOBAL DEFAULT 00 (1 day)