3
www.elstat.io
2.1 Water ingress–advisory informationforF MEA analysis
Elstat products have been designed to minimise any risks associated with water ingress and all controllers are IPX5
certified.
The OEM or installer is responsible to ensure that local/country laws andregulatory requirements are met.
2.2 ems25+ andems25advanced userinterface
The user interface of the ems25+ and ems25advanced is as follows:
Indicator Functon Colour
1
Saving temperature
disable
on if the saving mode temperature is disabled.
The controller maintains ready mode temperature at all times
Red
2 Motion on when motion is detected Red
3 Compressor on when the compressor is running Green
The ems controller buttons access the menu to view parameter values, reset the ems controller, and to run test
routines.
Push buttons:
Button Name Functon
defrost
or
teach
ems25advanced: starts a defrost cycle.
ems25+: sets the ems controller to the daving mode for up to one
hour.
Set Selects menu options and scrolls through the parameters
Up
Increases the parameter values.
ems25+: Also exits the tech saving mode
Down
Scrolls down menus, decreases parameter values, and cancels
alarms