Technical data 25
3.7 Digital outputs
The digital outputs DA2 and DA3 can be configured as low or high frequen-
cy pulse or signal outputs.
The digital outputs DA1 and DA4 can exclusively be configured as low fre-
quency pulse or signal outputs.
3.7.1 Nominal data
Maximum switching voltage
Maximum switching current
3.7.2 LF pulse or signal outputs
3.7.3 HF pulse outputs
The use of outputs as high frequency output is only possible if an external
power supply has been connected (see chapter 0).
Only outputs 2 and 3 (terminals DA2 and DA3) can be used as high fre-
quency output.
If the HF output is fed via a FE260, the maximum output fre-
quency is limited to 500 Hz (depending on the configuration
of the outputs).