28 Technical data
3.10.2 ATEX marking
The plate for the "Ex" marking of the EK280 is located on the top panel of
the device housing.
3.10.2.1 Zone 1 (without integrated power supply unit)
Fig. 2
1 Manufacturer and address
2 Ex marking
3 Permissible ambient temperature
range
4 Identification number
5 Type designation of the device
6 Temperature class data
3.10.2.2 Zone 2 (with integrated power supply unit)
Fig. 3
1 Manufacturer and address
2 Ex marking
3 Permissible ambient temperature
range
4 Identification number
5 Type designation of the device
6 Ex zone data
7 Warning notices
73021250
Type EK280
Electrical parameters and batteries
see EC Type examination certificate
ELSTER GmbH
55252 Mainz- Kastel
II 1 G
Ex ia IIB T4 or T3 Ga
LCIE 11 ATEX 3027 X
T amb: -4C to +6C
T3 with radio module
T4 without radio module