72 Operation
If an encoder is connected:
If the meter reading changes every two seconds or less, the measurement
inaccuracy of Qm will be max. 1%.
If the meter reading changes every 200 seconds or less, the measurement
inaccuracy will be max. 10%. This can be reduced by decreasing the
measurement cycle (Serv. -> Device settings -> Measurement -> MCyc) by
up to 2% for MCyc = 4 seconds.
If the meter reading of the encoder does not change after 200 seconds, Qm
= "0" will be displayed.
6.4.4 "Admin" register (Administrator)
This register is used to display and check special device settings and con-
ditions. This application is provided for metering point operator.
Display
Meaning
User values
8
Sub-menu for user-specific parameters
Volume
Sub-menu for volume and the corresponding parameters
Volume con-
version
Sub-menu for volume conversion and the corresponding pa-
rameters
Measured va-
lues
Sub-menu for measured values and the corresponding pa-
rameters
Archives
Sub-menu for existing archives in the device
Status
Sub-menu for current status, status register and logs
Date and ti-
me
Sub-menu for date, time and the corresponding parameters
Batteries
Sub-menu for the device battery and the corresponding pa-
rameters
Inputs
Sub-menu for inputs and the corresponding parameters
Outputs
Sub-menu for all outputs and the corresponding parameters
Interfaces
Sub-menu for device interfaces
Device set-
tings
Sub-menu for all device settings
Identification
Sub-menu for the identification of the gas system
8
In the "User Values" sub-menu, the user can set up to 10 freely programmable parameters
and up to 12 freely programmable parameters in a further sub-menu within this list.