Assembly, Connection and Putting into Operation 49
Press the ENTER button The set value will start to flash.
Press one of the arrow keys or until the text "Input 2" starts to
flash.
Press the ENTER button to confirm the set value. The input value can
be deleted by pressing the ESC button.
2. Adjust the input mode of the high frequency pulse transducer:
Press the button to display "Md.I2".
Press the ENTER button The set value will start to flash.
Press one of the arrow keys or until the text "HF pulses" starts to
flash.
Press the ENTER button to confirm the set value. The input value can
be deleted by pressing the ESC button.
3. Adjust the cp value of the high frequency pulse transducer:
Press the button to display "cp.I2".
Press the ENTER button The set value will start to flash.
Move the cursor using the arrow keys or to the digits and change
these using the arrow keys or to the cp value of the pulse trans-
ducer connected to input 2.
Press the ENTER button to confirm the set value. The input value can
be deleted by pressing the ESC button.
4. Adjust the parameters for the low frequency pulse transducer:
Adjust the parameters for the low frequency pulse transducer on input 1
as described in chapter 5.3.1.2.
5.3.1.6 Setting the volume at measurement conditions
In order to control the recording of the volume at measurement conditions,
the EK280 meter can be set once to the same value as the gas meter if the
administrator lock is open. It is always possible to set the volume if the cali-
bration lock is open:
Open the administrator lock or the calibration lock
Move the cursor to the „Serv.“ tab and go to the value „VmA” (adjustable
volume at measurement conditions) via the following path:
Serv. Volume Actual volume Synchronization Vm VmA
Press the ENTER key One of the value digits flashes.
Move the cursor using the arrow keys or to the digits and change
these using the arrow keys or .
Once you have changed all of the digits, press the ENTER key in order
to confirm your entry. The entry can be cancelled by pressing the ESC
key.
In order to accept the set value, move the cursor to the value „Store“
Press the ENTER key „0“ flashes.