76 Operation
6.4.6.5 Main ā Content of the "Main" register
The content of the "Main" display register can be adjusted here.
The default setting is "volume+meas.ā. This corresponds to the content dis-
played in chapter 6.3.1.
- The following are displayed: Volume at base condi-
tions, volume at measurement conditions, pressure,
temperature, compressibility ratio factor and conversion
factor
- Format: 8 pre-decimal and 3 post-decimal places for
counters
- With short descriptions for each value
- The following are displayed: Volume at base conditions
and volume at measurement conditions
- Format: 8 pre-decimal and 3 post-decimal positions re-
spectively
- With short descriptions
- The following are displayed: Volume at base conditions
and volume at measurement conditions
- Format: 9 pre-decimal and 4 post-decimal places
- Without short descriptions
- The following are displayed: Volume at base condi-
tions, volume at measurement conditions, pressure,
temperature, flow at base conditions and actual flow
rate
- Format: 8 pre-decimal and 3 post-decimal places for
counters
- With short descriptions for each value
- The following are displayed: Volume at base condi-
tions, volume at measurement conditions, total meter
reading the original meter reading of the gas meter at
Input DE1, pressure, temperature, Conversion factor,
compressibility ratio factor, actual flow rate, flow at
base conditions, date and time
- The following are displayed: Volume at base condi-
tions, meter reading of the gas meter (Encoder), pres-
sure, temperature, compressibility ratio factor and con-
version factor
- Format: 8 pre-decimal and 3 post-decimal places for
counters
- With short descriptions for each value