AIRPLANE
FLIGHT
ABNORMAL
PROCEDURES
ANAC APPROVED 4-18
REVISION 15 code 01 Page 7
Copyright © by Embraer. Refer to cover page for details.
AVIONICS MAU 3B FAILURE
For landing configuration, set slat/flap to full and set V
REF FULL
.
CAUTION: MULTIPLY THE FULL FLAPS UNFACTORED LANDING
DISTANCE BY 1.20.
AVIONICS MAU 1 (2) (3) A (B) OVERHEAT
Pull the associated circuit breaker and accomplish the associated
Avionics MAU Failure Procedure.
AVIONICS MAU 1 (2) (3) FAN FAILURE
Do not takeoff.
COMMUNICATION MANAGEMENT SYSTEM
F
AILURE
Do not takeoff.
CREW WARNING SYSTEM FAULT
Do not takeoff.
DISPLAY CONTROL FAILURE
NOTE: - PFD selections of VOR, FMS, RA/BARO Minimuns and Baro
Setting will be locked at the last setting position prior to the
failure.
- Disregard altitude callouts from aural system.
- Use IESS for barometric setting and ILS approach.