RRP: Core switch blade (CR4S-8)
109
Removal and Replacement Procedures (RRPs)
4. Turn the core switch blade on by sliding the ON/OFF switch in
the left handle to the left, to cover the thumb screw.
5. Verify that the power LED is green (might require a few seconds).
If not, ensure that the core switch blade has power and is firmly
seated and that the ejectors are in the locked position.
6. Connect the cables to the new core switch blade. If ICL cables are
not used, insert EMI plugs into the cable sockets.
7. Replace the chassis door (“RRP: Chassis door”).
8. Pack the faulty core switch blade in the packaging provided with
the new core switch blade, and contact EMC Customer Service to
determine the return procedure.