Alarm log Boolean alarm limit (continued)Table 6-25:
Data point Boolean alarm unit
IsMeasSndSpdRangeA ... IsMeas-
SndSpdRangeD
TRUE
Freq1DataValidity ... Freq2DataValidity FALSE
QMeterValidity FALSE
QFlowValidity FALSE
QBaseValidity FALSE
IsAcqModuleError TRUE
IsHourlyLogFull,
IsDailyLogFull,
IsAuditLogFull,
IsSystemLogFull
TRUE
IsBatchDataRcvFailed TRUE
IsClkInvalid TRUE
System log
The Daniel 3410 Series Gas Ultrasonic Flow Meter meter logs all system messages in the
system log. The meter can store up to 3000 system records. The user can select whether
old, unread records can be overwritten by new records when the log becomes full via the
data point DoOverwriteUnreadSystemLog.
This point can be modified using the Daniel MeterLink Tools|Edit/Compare Configuration
screen. The default is to overwrite old, unread records. Refer to for information on reading
records and marking records as read. The data point IsSystemLogFull indicates whether or
not the system log is full and cannot overwrite old, unread records.
Repetitive system messages are prevented from filling up the system log. When a
particular system message occurs 3 times within 60 seconds, that system message is
suppressed until that message's frequency drops below the 3 times-per-60 sec rate. The
system log records indicate when a system message suppression is started and ended.
Options for reading daily and/or hourly log records
The options for reading daily and hourly log records are the same. The Daniel MeterLink
Logs/Reports|Meter Archive Logs screen indicates the number of daily records that are
available to read. Select the log type(s) to be collected via the Collect daily log and/or
Collect hourly log check boxes.
Select whether to collect all log records or the last specified number of daily records. Also,
select whether to collect all log data or just the data points required by the API Chapter 21
standard. lists the daily log data points and lists the hourly log data points. For both tables,
data points required by the API Chapter 21 standard are marked with an asterisk (*).