Daily log content (continued)Table 6-1:
Data point Content Log action
bit 31
bit 30
bit 29
bit 28
bit 27
bit 26
bit 25
bit 24
bit 23
bit 22
bits 21-19
bit 18
bit 17
bit 16
bit 15-10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
bits 2-0
(unused)
IsMeasSndSpdRange
IsAvgSoundVelRangeErr
IsMeterVelAboveMaxLmt
IsHardFailedA IsHardFailedB
IsHardFailedC IsHardFailedD
(unused)
IsSNRTooLow
(unused)
IsPressureInvalid
IsTemperatureInvalid
IsAnyLogFull
(unused)
IsReverseFlowDetected
IsBoreBuildupDetected
IsLiquidDetected
IsAbnormalProfileDetected
IsReverseFlowDetected
IsSndVelCompErr
AreGasPropertiesInvalidInUse
(unused)
Paths A-B, Dual-
path meters
Paths A-D, 4-path
meters
SndVelA,
SndVelB,
SndVelC
Flow-Gated
FlowVelA
FlowVelB,
FlowVelC,
Flow-Gated
AvgFlow Flow-Gated
(Percent of good batch sig-
nals) PctGoodA1,PctGoo-
dA2 PctGoodB1,
PctGoodB2,
PctGoodC1,PctGoodC2,Pct
GoodD1,PctGoodD2
Average
QFlow Flow-Gated
QBase Flow-Gated