10.2 HART
Translation
HART/operating matrix
Measured
value
Empty
calibration
Full
calibration
Application
parameter
Output
damping
Value for
4 mA
Value for
20 mA
Measured
distance
Measured
value
Suppression
distance
Echo
quality
Microfactor
Fist echo
factor
Window
suppression
Offset*
Echo
suppression
Calibration
1 (V0)
1 (H0)
Matrix Group Select
2 (H1)
4 (H3)3 (H2) 5 (H4) 6 (H5) 7 (H6) 8 (H7) 9 (H8) 10 (H9)
2 (V2)
3 (V3)
5 (V8)
4 (V7)
Lineari-
sation
Extended
Calibration
Input level Input
volume
Line No.Lineari-
sation
Max.
volume
Safety
alarm
Last
diag.code
Units
Comm/soft-
version
LockingResetHART
address
Simulation
Simulation
value
Output
current
Diagnosis
Code
Tag No.
6 (V9)
7(VA)
Operating
mode
Service
Simulation
Communi-
cation
Length
units
In safety
distance
Plausibility
Output
min. 4 mA
Delay on
lost echo
Display text H-position has changed
BA171E67
Matrix HART menu Matrix HART menu Matrix HART menu
1 Basic calibration 3 Extended calibration 6 Simulation
V0H0 1 Measured value V3H0 1 Echo suppression V9H0 1 Diagnosis code
V0H1 2 Empty calibration V3H1 2 Suppression distance V9H1 2 Last diagnosis code
V0H2 3 Full calibration V3H2 3 Echo quality V9H3 3 Comm/software no.
V0H3 4 Application parameter V3H3 4 Microfactor V9H4 4 HART address
V0H4 5 Output damping V3H4 4 First echo factor V9H5 5 Reset
V0H5 6 Value for 4 mA V3H5 5 Window suppression V9H6 6 Simulation mode
V0H6 7 Value for 20 mA V3H6 6 Offset* V9H7 7 Simulation value
V0H7 8 Safety alarm 4 Service V9H8 8 Output current
V0H8 9 Measured distance 5 Operating mode V9H9 9 Security lock
V0H9 10 Level V8H1 1 Current output 4 mA 7 Communication
2 Linearisation V8H2 2 Length unit VAH0 1 Tag No.
V2H0 1 Linearisation mode V8H3 3 Delay on lost echo VAH3 2 Level unit
V2H1 2 Line No. V8H5 4 In safety distance
V2H2 3 Enter level V8H6 5 Plausibility
V2H3 4 Enter volume
V2H5 5 Tank volume
* Not required for rod antenna
Note!
Slight differences between the matrix and the menu texts are
possible
Micropilot FMR 231 Chapter 10 Operating Matrix