Technical data Proline Promag P 500 HART
186 Endress+Hauser
Electrical conductivity
Max. ±5 % o.r.
Influence of ambient
temperature
Current output
Temperature coefficient Max. 1 μA/°C
Pulse/frequency output
Temperature coefficient No additional effect. Included in accuracy.
16.7 Installation
"Mounting requirements"
16.8 Environment
Ambient temperature
range
→  26
Temperature tables
Observe the interdependencies between the permitted ambient and fluid
temperatures when operating the device in hazardous areas.
For detailed information on the temperature tables, see the separate document
entitled "Safety Instructions" (XA) for the device.
Storage temperature –50 to +80 °C (–58 to +176 °F)
Protect the measuring device against direct sunlight during storage in order to avoid
unacceptably high surface temperatures.
Select a storage location where moisture cannot collect in the measuring device as
fungus or bacteria infestation can damage the liner.
If protection caps or protective covers are mounted these should never be removed
before installing the measuring device.
Degree of protection Transmitter
As standard: IP66/67, type 4X enclosure
When housing is open: IP20, type 1 enclosure
Display module: IP20, type 1 enclosure
Sensor
As standard: IP66/67, type 4X enclosure
External WLAN antenna
IP67
Vibration resistance Vibration, sinusoidal according to IEC 60068-2-6
2 to 8.4 Hz, 7.5 mm peak
8.4 to 2 000 Hz, 2 g peak
Vibration broad-band random, according to IEC 60068-2-64
10 to 200 Hz, 0.01 g
2
/Hz
200 to 2 000 Hz, 0.003 g
2
/Hz
Total: 2.70 g rms