Parameter Prerequisite Description User interface
Temperature One of the following conditions is met:
• Order code for "Sensor option", option
CI "Medium temperature
measurement"
or
• The temperature is read into the
flowmeter from an external device.
Displays the temperature currently
calculated.
Dependency
The unit is taken from the
Temperature unit parameter
(→ 97).
Positive floating-point
number
Density – Displays the current fixed density or
density read in from an external device.
Dependency
The unit is taken from the Density unit
parameter.
Signed floating-point
number
11.4.2 "Totalizer" submenu
The Totalizer submenu contains all the parameters needed to display the current
measured values for every totalizer.
Navigation
"Diagnostics" menu → Measured values → Totalizer
‣
Totalizer
Totalizer value 1 to n
→ 138
Totalizer overflow 1 to n
→ 138
Parameter overview with brief description
Parameter Prerequisite Description User interface
Totalizer value 1 to n A process variable is selected in the
Assign process variable parameter
(→ 120) of the Totalizer 1 to n
submenu.
Displays the current totalizer counter
value.
Signed floating-point
number
Totalizer overflow 1 to n A process variable is selected in the
Assign process variable parameter
(→ 120) of the Totalizer 1 to n
submenu.
Displays the current totalizer overflow. Integer with sign
11.4.3 "Input values" submenu
The Input values submenu guides you systematically to the individual input values.
Navigation
"Diagnostics" menu → Measured values → Input values
‣
Input values
‣
Current input 1 to n
→ 139
‣
Status input 1 to n
→ 139