Proline Promag P 500 HART Technical data
Endress+Hauser 187
Shock resistance Shock, half-sine according to IEC 60068-2-27
6 ms 50 g
Impact resistance Rough handling shocks according to IEC 60068-2-31
Mechanical load • Protect the transmitter housing against mechanical effects, such as shock or impact.
• Never use the transmitter housing as a ladder or climbing aid.
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.
16.9 Process
Medium temperature range • –20 to +150 °C (–4 to +302 °F) for PFA, DN 25 to 200 (1 to 8")
• –20 to +180 °C (–4 to +356 °F) for PFA high-temperature, DN 25 to 200 (1 to 8")
• –40 to +130 °C (–40 to +266 °F) for PTFE, DN 15 to 600 (½ to 24")
0
0
0
0
-20-40
-40
20
20
40
100
60
140
[°F] [°C]
40 60 80 100
100
120 140 160
200 300
180
360
-20
-40
-40
T
A
T
F
[°F]
[°C]
2
1
3 4
A0029347
50 PFA
T
A
Ambient temperature range
T
F
Fluid temperature
1 Colored area: the ambient temperature range –10 to –20 °C (+14 to –4 °F) applies to stainless flanges only
2 Hatched area: harsh environment IP69 only for fluid temperature range –20 to +130 °C (–4 to +266 °F)
3 –20 to +150 °C (–4 to +302 °F) for PFA, DN 25 to 200 (1 to 8")
4 –20 to +180 °C (–4 to +356 °F) for PFA high-temperature, DN 25 to 200 (1 to 8")