Proline Promag P 500 HART Operation
Endress+Hauser 137
Corrected volume flow
→ 137
Flow velocity
→ 137
Conductivity
→ 137
Corrected conductivity
→ 137
Temperature
→ 138
Density
→ 138
Parameter overview with brief description
Parameter Prerequisite Description User interface
Volume flow – Displays the volume flow currently
measured.
Dependency
The unit is taken from the Volume flow
unit parameter (→ 97).
Signed floating-point
number
Mass flow – Displays the mass flow currently
calculated.
Dependency
The unit is taken from the Mass flow
unit parameter (→ 97).
Signed floating-point
number
Corrected volume flow – Displays the corrected volume flow
currently calculated.
Dependency
The unit is taken from the Corrected
volume flow unit parameter
(→ 97).
Signed floating-point
number
Flow velocity – Displays the flow velocity currently
calculated.
Signed floating-point
number
Conductivity – Displays the conductivity currently
measured.
Dependency
The unit is taken from the Conductivity
unit parameter (→ 97).
Signed floating-point
number
Corrected conductivity One of the following conditions is met:
• Order code for "Sensor option", option
CI "Medium temperature
measurement"
or
• The temperature is read into the
flowmeter from an external device.
Displays the conductivity currently
corrected.
Dependency
The unit is taken from the Conductivity
unit parameter (→ 97).
Positive floating-point