Liquiline CM44P System integration
Endress+Hauser 51
10. If you use a proxy server to connect to the internet:
Disable the proxy (browser settings under "Connections/LAN settings").
11. Enter the IP address of your device in the address bar (192.168.1.212 in the
example).
The system takes a few moments to establish the connection and then the CM44
web server starts. You might be asked for a password. The factory setting is
"admin" for the user name and "admin" for the password.
12. Enter the following address(es) to download logbooks:
192.168.1.212/logbooks_csv.fhtml (for logbooks in CSV format)
192.168.1.212/logbooks_fdm.fhtml (for logbooks in FDM format)
Downloads in FDM format can be securely transmitted, saved and visualized with
Endress+Hauser's "Field Data Manager Software".
(→ www.endress.com/ms20)
7.1.3 Operation
The menu structure of the web server corresponds to the onsite operation.
A0026780
79 Example of web server (menu/language=English)
• Clicking a menu name or a function corresponds to pressing the navigator.
• You can make your settings conveniently via the computer keyboard.
Instead of using an internet browser, you can also use FieldCare for configuration via
Ethernet. The Ethernet DTM required for this is an integral part of the "Endress
+Hauser Interface Device DTM Library".
Download: https://portal.endress.com/webdownload/FieldCareDownloadGUI/
7.2 Service interface
You can connect the device to a computer via the service interface and configure it using
"FieldCare" . Furthermore, configurations can also be saved, transferred and documented.
7.2.1 Connection
1. Connect the service connector to the interface on the Liquiline base module and
connect it to the Commubox.
2. Connect the Commubox via the USB connection to the computer on which FieldCare
is installed.