EasyManua.ls Logo

Endress+Hauser Micropilot FMR62 - Supply Voltage

Endress+Hauser Micropilot FMR62
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR62
22 Endress+Hauser
Supply voltage
An external power supply is necessary.
Various power supply units can be ordered as an accessory from Endress+Hauser.
2-wire, 4-20 mA HART, passive
"Power
supply,
output"
1)
"Approval"
2)
Terminal
voltage U at
device
Maximum load R,
Depends on the supply voltage
U
0
of power supply unit
A:
2-wire;
4-20 mA
HART
Non-Ex
Ex ec
Ex ic
CSA GP
14 to 35 V
3)
R [ ]W
U
0
[V]
10
14
25
20 30 35
0
500
A0031745
Ex ia / IS 14 to 30 V
3)
Ex db(ia) /
XP
Ex ic(ia)
Ex ec(ia)
Ex ta / DIP
14 to 35 V
3) 4)
Ex ia + Ex
db(ia) / IS +
XP
14 to 30 V
3)
1) Feature 020 in the product structure
2) Feature 010 in the product structure
3) If the Bluetooth module is used, the minimum supply voltage increases by 2 V.
4) At ambient temperatures T
a
≤ –20 °C, a terminal voltage U ≥ 16 V is required to start the device with the
minimum failure current (3.6 mA).
"Power
supply,
output"
1)
"Approval"
2)
Terminal
voltage U at
device
Maximum load R,
Depends on the supply voltage
U
0
of power supply unit
B:
2-wire;
4-20 mA
HART,
switch
output
Non-Ex
Ex ec
Ex ec(ia)
Ex ic
Ex ic(ia)
Ex db(ia) /
XP
Ex ta / DIP
CSA GP
16 to 35 V
3)
R [ ]W
U
0
[V]
10
16
27
20 30 35
0
500
A0031746
Ex ia / IS
Ex ia + Ex
d(ia) / IS +
XP
16 to 30 V
3)
1) Feature 020 in the product structure
2) Feature 010 in the product structure
3) If the Bluetooth module is used, the minimum supply voltage increases by 2 V.

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR62

Related product manuals