EasyManua.ls Logo

Endress+Hauser Micropilot FMR62 - Storage Temperature; Climate Class; Altitude According to IEC61010-1 Ed.3; Degree of Protection

Endress+Hauser Micropilot FMR62
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR62
40 Endress+Hauser
FMR62
Antenna
1)
GE:
Integrated, PEEK, 3/4"
GF:
Integrated, PEEK, 1-1/2"
GM:
PTFE cladded flush mount DN50
GN:
PTFE cladded flush mount DN80
T
a
T
p
P2
+
P1
P2
P3
P4
P5
A0032025
Seal
2)
A5:
FKM Viton GLT,
–40 to 150 °C (–40 to 302 °F)
C1:
FFKM Kalrez,
–40 to 150 °C (–40 to 302 °F)
F5:
PTFE cladded,
–40 to 150 °C (–40 to 302 °F)
Temperature specifications: °C (°F)
Housing type
3)
P1 P2 P2+ P3 P4 P5
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
B:
GT18 dual compartment
316L
–40
(–40)
76
(168.8)
76
(168.8)
76
(168.8)
109
(228.2)
71
(159.8)
150
(302)
47
(116.6)
150
(302)
–40
(–40)
–40
(–40)
–40
(–40)
A:
GT19 dual compartment
Plastic PBT
–40
(–40)
60
(140)
60
(140)
60
(140)
127
(260.6)
45
(113)
150
(302)
24
(75.2)
150
(302)
–40
(–40)
–40
(–40)
–40
(–40)
C:
GT20 dual compartment
Aluminum, coated
–40
(–40)
76
(168.8)
76
(168.8)
76
(168.8)
112
(233.6)
72
(161.6)
150
(302)
55
(131)
150
(302)
–40
(–40)
–40
(–40)
–40
(–40)
1) Feature 070 in the product structure
2) Feature 090 in the product structure
3) Feature 040 in the product structure
Storage temperature
–40 to +80 °C (–40 to +176 °F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Altitude according to
IEC61010-1 Ed.3
Generally up to 2 000 m (6 600 ft) above MSL.
Above 2 000 m (6 600 ft) if the following conditions are met:
Ordering feature 020 "Power supply; Output" = A, B, C, E or G (2-wire versions)
Supply voltage U < 35 V
Supply voltage of overvoltage category 1
Degree of protection
When housing is closed, tested according to:
IP68, NEMA6P (24 h at 1.83 m under water)
For plastic housing with see-through lid (display): IP68 (24 h at 1.00 m under water)
This restriction applies if the following options have been selected simultaneously in the product
structure: 030 ("Display/operation") = C ("SD02") or E ("SD03"); 040 ("Housing") = A ("GT19").
IP66, NEMA4X
With housing open: IP20, NEMA1
Display module: IP22, NEMA2
Degree of protection IP68 NEMA6P only applies for M12 PROFIBUS PA plugs if the
PROFIBUS cable is plugged in and is also rated IP68 NEMA6P.