Micropilot FMR62
34 Endress+Hauser
100%
0%
A
150…500
(5.91...19.7)
4
B
C
3
2
5
1
1 (0.04)
A0042913
 16 Example of stilling well design. Unit of measurement mm (in)
A Micropilot FMR62 80mm/3" antenna
B Stilling well with slots
C Full bore ball valve
1 e.g. welding neck flange DIN2633
2 Borehole always deburred
3 Ø bore max. 1/10 Ø pipe; on one side or drilled through
4 Slot width max. 1/10 Ø pipe; slot: on one side or drilled through
5 Opening diameter of ball valve must always correspond to the pipe diameter; avoid edges and constrictions.