Loading...
Micropilot FMR62
Endress+Hauser 51
FMR62: Flush-mounted antenna with Tri-Clamp connection, PTFE-clad
øD2
øD1
L1
L2
L4
1
1
øD3
2.6 (0.10)
1.6 (0.06)
A
B
R
A0032176
 30 Dimensions of antenna with Tri-Clamp connection, PTFE-clad. Unit of measurement mm (in)
A Seal: PTFE cladded, -40 to 150°C/-40 to 302°F
B Seal: PTFE cladded, -40 to 200°C/-40 to 392°F
R Reference point of measurement
1 Bottom edge of housing
Feature 70 "Antenna" øD1 L1 L2 L4
GM:
PTFE cladded flush mount DN50
47.5 mm (1.87 in) 145 mm (5.71 in) 188 mm (7.40 in) 19 mm (0.75 in)
GN:
PTFE cladded flush mount DN80
75 mm (2.95 in) 158 mm (6.22 in) 201 mm (7.91 in) 32 mm (1.26 in)
Tri-Clamp connection as per ISO2852
Feature 100 "Process connection" Nominal diameter Pipe inner diameter øD2 øD3
TDK: DN51 (2") DN51 48.6 mm (1.91 in) 56.5 mm (2.22 in) 64 mm (2.52 in)
TFK: DN70-76.1 (3")
DN70 66.8 mm (2.63 in)
83.5 mm (3.29 in) 91 mm (3.58 in)
DN76.1 72.9 mm (2.87 in)
THK: DN101.6 (4") DN101.6 97.6 mm (3.84 in) 110 mm (4.33 in) 119 mm (4.69 in)
Tri-Clamp connection as per DIN32676 Series C or ASME BPE
Feature 100 "Process connection" Nominal diameter Pipe inner diameter øD2 øD3
TDK: DN51 (2") 2" 47.5 mm (1.87 in) 56.5 mm (2.22 in) 64 mm (2.52 in)
TFK: DN70-76.1 (3") 3" 72.9 mm (2.87 in) 83.5 mm (3.29 in) 91 mm (3.58 in)
THK: DN101.6 (4") 4" 97.38 mm (3.83 in) 110 mm (4.33 in) 119 mm (4.69 in)