10 Technical data PROline Promag 50
134 Endress+Hauser
Promag H / DN 2...25 (remote version)
Fig. 69: Dimensions Promag H / DN 2...25 (remote version)
Dimensions wall-mounted housing
seePage122
Wall mounting set for Promag H / DN 2…25
Fig. 70: Wall mounting set for Promag H / DN 2…25
A = 125 mm, B = 88 mm, C = 120 mm, D = Ø 7 mm
DN PN * DI L A B C K M
[mm] [inch] [bar] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
2
16/40 2.25 86 213 148 65 43 M 6x4
4
16/40 4.5 86 213 148 65 43 M 6x4
8
16/40 9.0 86 213 148 65 43 M 6x4
15
16/40 16.0 86 213 148 65 43 M 6x4
1" 16/40 22.6 86 213 148 65 53 M 6x4
26
16/40 26.0 86 213 148 65 53 M 6x4
Overall fitting length will depend on the process connections
Page 137 ff.
* The permissible nominal pressure depends on the process connection and seal:
40 bar: flange EN 1092-1 (DIN 2501), welded nipples for DIN EN ISO 1127 pipes and ODT
(with O-ring seal)
16 bar: all other process connections
L
A
C
B
K
DI
M
125
75
70
F06-5xHxxxxx-06-05-xx-xx-001
A
B
C
D
F06-xxHxxxxx-06-07-06-xx-000

Table of Contents