PROline Promag 50 10 Technical data
Endress+Hauser 141
Process connections with aseptic gasket seal (DN 2…25 )
Weld nipple for DIN
1.4404 / 316L
5*H**-U***********
Sensor Fits to di G L H x B
DN [mm] Piping DIN 11850 [mm] [mm] [mm] [mm]
2…8 14 x 2 10 14 23.3 60 x 42
15 20 x 2 16 20 23.3 60 x 42
25 (DIN) 30 x 2 26 30 23.3 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
L
H x B
F06-xxHxxxxx-06-09-07-xx-011
Weld nipples for ODT/SMS
1.4404 / 316L
5*H**-V***********
Sensor Fits to di G L H x B
DN [mm] Piping OD / SMS [mm] [mm] [mm] [mm]
2…8 12.7 x 1.65 9.4 12.7 16.1 60 x 42
15 19.1 x 1.65 15.8 19.1 16.1 60 x 42
25 (1" ANSI) 24.5 x 1.65 22.1 25.4 16.1 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
L
H x B
F06-xxHxxxxx-06-09-07-xx-013
Clamp ISO 2852, Fig. 2
1.4404 / 316L
5*H**-W***********
Sensor Fits to ISO 2852 di G L H x B
DN [inch] Piping ISO 2037 /
BS 4825-1
Diameter
[mm]
[mm] [mm] [mm] [mm]
25 (1" ANSI) Tube 25.4 x 1.65 25 22.6 50.5 44.5 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
H x B
L
F06-xxHxxxxx-06-09-07-xx-023
Clamp DIN 32676
1.4404 / 316L
5*H**-0***********
Sensor Fits to di G L H x B
DN [mm] Piping DIN 11850 [mm] [mm] [mm] [mm]
2…8 Tube 14 x 2 (DN 10) 10 34.0 41.0 60 x 42
15 Tube 20 x 2 (DN 15) 16 34.0 41.0 60 x 42
25 (DIN) Tube 30 x 2 (DN 25) 26 50.5 44.5 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
L
H x B
F06-xxHxxxxx-06-09-07-xx-019