10 Technical data PROline Promag 50
142 Endress+Hauser
Tri-clamp L14 AM7
1.4404 / 316L
5*H**-1***********
Sensor Fits to di G L H x B
DN [mm] Piping OD [mm] [mm] [mm] [mm]
2…8 Tube 12.7 x 1.65
(ODT 1/2")
9.4 25.0 28.5 60 x 42
15 Tube 19.1 x 1.65
(ODT 3/4")
15.8 25.0 28.5 60 x 42
25 (1" ANSI) Tube 25.5 x 1.65
(ODT 1")
22.1 50.4 28.5 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
L
H x B
F06-xxHxxxxx-06-09-07-xx-020
Coupling:
Threaded adapter SC DIN 11851
1.4404 / 316L
5*H**-2***********
Sensor Fits to di G L H x B
DN [mm] Piping DIN 11850 [mm] [mm] [mm] [mm]
2…8 Tube 12 x 1
(DN 10)
10 Rd 28 x 1/8" 44 60 x 42
15 Tube 18 x 1 or 1.5
(DN 15)
16 Rd 34 x 1/8" 44 60 x 42
25 (DIN) Tube 28 x 1 or 1.5
(DN 25)
26 Rd 52 x 1/6" 52 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
H x B
L
F06-xxHxxxxx-06-09-07-xx-017
Coupling DIN 11864-1:
Aseptic threaded adapter, Form A
1.4404 / 316L
5*H**-3***********
Sensor Fits to di G L H x B
DN [mm] Piping DIN 11850 [mm] [mm] [mm] [mm]
2…8 Tube 13 x 1.5 (DN 10) 10 Rd 28 x 1/8" 42 60 x 42
15 Tune 19 x 1.5 (DN 15) 16 Rd 34 x 1/8" 42 60 x 42
25 (DIN) Tube 29 x 1.5 (DN 25) 26 Rd 52 x 1/6" 49 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
L
H x B
F06-xxHxxxxx-06-09-07-xx-021
Flange DIN 11864-2
Aseptic grooved flange, Form A
1.4404 / 316L
5*H**-4***********
Sensor Fits to di G L LK M H x B
DN [mm] Piping DIN 11850 [mm] [mm] [mm] [mm] [mm] [mm]
2…8 Tube 13 x 1.5 (DN 10) 10 54 48.5 37 9 60 x 42
15 Tube 19 x 1.5 (DN 15) 16 59 48.5 42 9 60 x 42
25 (DIN) Tube 29 x 1.5 (DN 25) 26 70 48.5 53 9 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 133)
and process connection (di) into account.
G
di
LK
L
H x B
M
F06-xxHxxxxx-06-09-07-xx-022