EasyManua.ls Logo

Endress+Hauser Proline Promag 55 - Quick Setup Communication

Endress+Hauser Proline Promag 55
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device functions Proline Promag 55 FOUNDATION Fieldbus 3 Transducer Block
Endress+Hauser 79
System Value -
Volume Flow
read only Use this parameter to view the current volume flow.
The volume flow is made available as a process variable to the
downstream Analog Input function blocks.
! Note!
The unit is displayed in the "System Unit - Volume Flow" parameter
(Page 79).
System Unit -
Volume Flow
AUTO - OOS Use this parameter to select the unit for the volume flow (volume/time).
The unit you select here is also valid for:
Simulation
Low flow cut off
Display value (local display)
Options:
Metric:
Cubic centimeter cm
3
/s; cm
3
/min; cm
3
/h; cm
3
/day
Cubic decimeter dm
3
/s; dm
3
/min; dm
3
/h; dm
3
/day
Cubic meter m
3
/s; m
3
/min; m
3
/h; m
3
/day
Milliliter ml/s; ml/min; ml/h; ml/day
Liter l/s; l/min; l/h; l/day
Hectoliter hl/s; hl/min; hl/h; hl/day
Megaliter Ml/s; Ml/min; Ml/h; Ml/day
US:
Cubic centimeter cc/s; cc/min; cc/h; cc/day
Acre foot af/s; af/min; af/h; af/day
Cubic foot ft
3
/s; ft
3
/min; ft
3
/h; ft
3
/day
Fluid ounce oz f/s; oz f/min; oz f/h; oz f/day
Gallon gal/s; gal/min; gal/h; gal/day
Kilo gallon Kgal/s; Kgal/min; Kgal/h; Kgal/day
Million gallon Mgal/s; Mgal/min; Mgal/h; Mgal/day
Barrel (normal fluids: 31.5 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Barrel (beer: 31.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Barrel (petrochemicals: 42.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Barrel (filling tanks: 55.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Imperial:
Gallon gal/s; gal/min; gal/h; gal/day
Mega gallon Mgal/s; Mgal/min; Mgal/h; Mgal/day
Barrel (beer: 36.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Barrel (petrochemicals: 34.97 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Factory setting:
Nominal diameter and country dependentPage 123 ff.
! Note!
The unit selected here does not have any effect on the desired volume
unit which should be transmitted by means of the FOUNDATION
Fieldbus interface. This setting is made separately by means of the
corresponding AI Block in the XD_SCALE parameter group.
System Value -
Mass Flow
read only Use this function to view the calculated mass flow.
The mass flow is derived from the measured volume flow and the fixed
density value (Page 87). The calculated mass flow is made available
as a process variable to the downstream Analog Input function blocks.
! Note!
The unit is displayed in the "System Unit - Mass Flow" parameter
(Page 80).
"Flow" Transducer Block/base index 1400
Parameter
Write access with
operating mode
(MODE_BLK)
Description

Table of Contents

Other manuals for Endress+Hauser Proline Promag 55