3 Transducer Block Device functions Proline Promag 55 FOUNDATION Fieldbus
80 Endress+Hauser
System Unit -
Mass Flow
AUTO - OOS Use this parameter to select the unit for the mass flow (mass/time).
The unit you select here is also valid for:
Simulation
Low flow cut off
Display value (local display)
Options:
Metric:
gram g/s; g/min; g/h; g/day
kilogram kg/s; kg/min; kg/h; kg/day
Metric ton t/s; t/min; t/h; t/day
US:
ounce oz/s (US); oz/min (US); oz/h (US); oz/day (US)
pound lb/s; lb/min; lb/h; lb/day
ton ton/s; ton/min; ton/h; ton/day
Factory setting:
Nominal diameter and country dependentPage 123 ff.
! Note!
The unit selected here does not have any effect on the desired mass flow
unit which should be transmitted by means of the FOUNDATION
Fieldbus interface. This setting is made separately by means of the
corresponding AI Block in the XD_SCALE parameter group.
System Value -
Fixed Density
read only Use this function to view the set density.
This density value can be modified by means of the "Density Param. -
Fixed Value" parameter (Page 87).
Factory setting:
1
! Note!
The unit is displayed in the "System Unit - Fixed Density" parameter
(Page 80).
System Unit -
Fixed Density
AUTO - OOS Use this parameter to select the unit for displaying the fluid density.
The unit you select here is also valid for:
Density entry "Density Param. - Fixed Value", Page 87)
Options:
Metric g/cm
3
; g/cc; kg/dm
3
; kg/l; kg/m
3
; SD 4 °C, SD 15 °C,
SD 20 °C; SG 4 °C, SG 15 °C, SG 20 °C; g/l
US lb/ft
3
; lb/gal; lb/bbl (normal fluids); lb/bbl (beer); lb/bbl
(petrochemicals);
lb/bbl (filling tanks)
Imperial lb/gal; lb/bbl (beer); lb/bbl (petrochemicals)
Factory setting:
kg/l (SI units: not for USA and Canada)
g/cc (US units: only for USA and Canada)
SD = Specific Density, SG = Specific Gravity
The specific density is the ratio of fluid density to water density
(at water temperature = 4, 15, 20 °C).
"Flow" Transducer Block/base index 1400
Parameter
Write access with
operating mode
(MODE_BLK)
Description