EasyManua.ls Logo

Endress+Hauser Proline Promass E 100 - Pin Assignment, Device Plug

Endress+Hauser Proline Promass E 100
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass E 100
30 Endress+Hauser
Safety Barrier Promass 100
A
Safe area
1
L+
2
L
27
26
B A
Power
supply
24V
DC
Modbus
RS485
1020
72
62
L+L B A
Power
supply
Modbus
RS485
Hazardous area
Safety Barrier
Promass 100
Power
Communication
Lift panel for
bus termination
1
2
A
A0030220
 8 Safety Barrier Promass 100 with terminals
1
Non-hazardous area, Zone 2, Class I Division 2
2 Intrinsically safe area
Pin assignment, device plug
Order codes for the M12x1 connectors, see the "Order code for electrical connection" column:
4-20 mA HART, pulse/frequency/switch output →
 23
PROFIBUS DP→  25
Modbus RS485 →  26
EtherNet/IP →  28
PROFINET→  29
Supply voltage
For all connection versions except MODBUS RS485 intrinsically safe (device side)
Device plug MODBUS RS485 intrinsically safe with supply voltage →  31
1
2
4
3
5
A0016809
Pin Assignment
1 L+ DC 24 V
2 Not assigned
3 Not assigned
4 L- DC 24 V
5 Grounding/shielding
Coding Plug/socket
A Plug
The following is recommended as a socket:
Binder, series 763, part no. 79 3440 35 05
Alternatively: Phoenix part no. 1669767 SAC-5P-M12MS
With the order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output
With the order code for "Output", option N: EtherNet/IP
When using the device in a hazardous location: Use a suitably certified socket.