EasyManua.ls Logo

Endress+Hauser Proline Promass I 300 - Page 143

Endress+Hauser Proline Promass I 300
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass I 300 PROFINET Operation
Endress+Hauser 143
Parameter Prerequisite Description User interface
Corrected volume flow Displays the corrected volume flow that
is currently calculated.
Dependency
The unit is taken from the Corrected
volume flow unit parameter
(→  94).
Signed floating-point
number
Density Shows the density currently measured.
Dependency
The unit is taken from the Density unit
parameter (→  94).
Signed floating-point
number
Reference density Displays the reference density that is
currently calculated.
Dependency
The unit is taken from the Reference
density unit parameter (→  94).
Signed floating-point
number
Temperature Shows the medium temperature
currently measured.
Dependency
The unit is taken from the
Temperature unit parameter
(→  95).
Signed floating-point
number
Pressure value Displays either a fixed or external
pressure value.
Dependency
The unit is taken from the Pressure
unit parameter (→  95).
Signed floating-point
number
Dynamic viscosity For the following order code:
"Application package", option EG
"Viscosity"
The software options currently
enabled are displayed in the
Software option overview
parameter.
Displays the dynamic viscosity that is
currently calculated.
Dependency
The unit is taken from the Dynamic
viscosity unit parameter.
Signed floating-point
number
Kinematic viscosity For the following order code:
"Application package", option EG
"Viscosity"
The software options currently
enabled are displayed in the
Software option overview
parameter.
Displays the kinematic viscosity that is
currently calculated.
Dependency
The unit is taken from the Kinematic
viscosity unit parameter.
Signed floating-point
number
Temp. compensated dynamic
viscosity
For the following order code:
"Application package", option EG
"Viscosity"
The software options currently
enabled are displayed in the
Software option overview
parameter.
Displays the temperature compensation
that is currently calculated for the
viscosity.
Dependency
The unit is taken from the Dynamic
viscosity unit parameter.
Signed floating-point
number
Temp. compensated kinematic
viscosity
For the following order code:
"Application package", option EG
"Viscosity"
The software options currently
enabled are displayed in the
Software option overview
parameter.
Displays the temperature compensation
that is currently calculated for the
kinetic viscosity.
Dependency
The unit is taken from the Kinematic
viscosity unit parameter (0578).
Signed floating-point
number

Table of Contents