Accessories Proline Prosonic Flow 91
46 Endress+Hauser
8 Accessories
Various accessories, which can be ordered separately from Endress+Hauser, are available for the
transmitter and the sensor. Your Endress+Hauser service organization can provide detailed
information on the order code in question.
8.1 Device-specific accessories
8.2 Accessories specific to measuring principle
Accessory Description Order code
Sensor W
(DN 50 to 4000)
Clamp-on version
DN 50 to 300, –20 to +80 °C (2" to 12", –4 to +176 °F)
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - B*
DK9WS - N*
DN 100 to 4000, –20 to +80 °C (4" to 160", –4 to +176 °F)
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - A*
DK9WS - M*
DN 100 to 4000, 0 to +130 °C (4" to 160", +32 to +266 °F)
• IP 67 / NEMA 4X DK9WS - P*
DN 50 to 300, 0 to +130 °C (2" to 12", +32 to +266 °F)
• IP 67 / NEMA 4X DK9WS - S*
Accessory Description Order code
Mounting kit for
aluminum field housing
Mounting kit for wall-mount housing. DK9WM - C
Sensor holder set • Prosonic Flow W (DN 50 to 4000, 2" to 160")
– Sensor holder, fixed retaining nut, clamp-on version DK9SH - A
Clamp-on installation set
Clamp On
Sensor fastening for Prosonic Flow W
(DN 50 to 4000, 2" to 160")
• Without sensor fastening
• Strapping bands DN 50 to 200 (2" to 8")
• Strapping bands DN 200 to 600 (8" to 24")
• Strapping bands DN 600 to 2000 (24" to 80")
• Strapping bands DN 2000 to 4000 (80" to 160")
DK9IC - A*
DK9IC - B*
DK9IC - C*
DK9IC - D*
DK9IC - E*
Without mounting tools
• Spacing ruler DN 50 to 200 (2" to 8")
• Spacing ruler DN 200 to 600 (8" to 24")
• Fastener, 1 Traverse DN 50 to 4000 (2" to 160")
DK9IC - *1
DK9IC - *2
DK9IC - *3
DK9IC - *6
Conduit adapter for
connecting cable
Prosonic Flow W (DN 50 to 4000)
• Conduit adapter incl. cable entry M20× 1,5
• Conduit adapter incl. cable entry ½" NPT
• Conduit adapter incl. cable entry G ½"
DK9CB - AB1
DK9CB - AB2
DK9CB - AB3
Connecting cable 5 m (16 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
10 m (33 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
15 m (49 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
30 m (98 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
60 m (197 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
DK9SS - ABA
DK9SS - ABB
DK9SS - ABC
DK9SS - ABD
DK9SS - ABJ
Acoustic coupling fluid • Coupling fluid 0 to 170 °C (+32 to 338 °F), Standard
• Adhesive coupling fluid –40 to +80 °C (–40 to 176 °F)
• Water-soluble coupling fluid –20 to +80 °C (–4 to 176 °F)
• SilGel –40 to +130 °C (–40 to +266 °F)
• Coupling fluid DDU 19, –20 to +60 °C (–4 to 140 °F)
• Coupling fluid –40 to +80 °C (–40 to 176 °F), Standard,
type MBG2000
DK9CM - 2
DK9CM - 3
DK9CM - 4
DK9CM - 5
DK9CM - 6
DK9CM - 7