Description of device functions Proline Prosonic Flow 91
70 Endress+Hauser
11.3 Group SENSOR SETUP
Functional description SENSOR SETUP
SETUP Picklist SENSOR SETUP:
•SETUP
•LIQUID
•PIPE DATA
•LINER
CONFIG. CHANNEL
POS. SENSOR
•QUIT
SETUP: LIQUID TEMPERATURE SOUND VEL. LIQUID
PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE
PIPE DIAMETER WALL THICKNESS LINER MATERIAL
SOUND VEL. LINER LINER THICKNESS SENSOR TYPE
SENSOR CONFIG. CABLE LENGTH POS.SENSOR/WIRE
LENGTH SENSOR DISTANCE
LIQUID:LIQUID TEMPERATURE SOUND VEL. LIQUID
PIPE DATA:PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE
PIPE DIAMETER WALL THICKNESS
LINER:LINER MATERIAL SOUND VEL. LINER
LINER THICKNESS
CONFIG. CHANNEL:SENSOR TYPE SENSOR CONFIG. CABLE LENGTH
POS.SENSOR:POS.SENSOR/WIRE LENGTH SENSOR DISTANCE
The following information is required for a successful setup:
Sound velocity of the liquid
Operating temperature
Pipe circumference or pipe outer diameter
Sound velocity of the pipe material
Wall thickness
Sound velocity of the lining material (if present)
Thickness of the lining (if present)
•Sensor type
Sensor arrangement (direct or reflection mode)
Length of the sensor cable
The relative sensor positions and the proportionality factor (meter factor) are determined
from these application-specific data.
The functionality of the device is ensured by correctly specifying the sound velocity of the
liquid, the nominal diameter of the pipe, the sensor type and the sensor arrangement,
provided the unit is mounted correctly.
The correct information for the sensor cable length and the wall and liner thickness
primarily affect the quality of the measurement.