POSITION SENSOR Use this function to view the position of both sensors on the rail.
Display:
4-digit number combination
!
Note!
This function is only available if the number of traverses is 2 or 4 (see function SENSOR
CONFIGURATION).
WIRE LENGTH The wire length for assembling the sensors at the correct distance apart appears on the
display.
Display:
max. 4-digit number, including unit (e.g. 200 mm)
!
Note!
This function is only available if the number of traverses is 1 (see function SENSOR
CONFIGURATION).
SENSOR DISTANCE The distance between sensor 1 and sensor 2 appears on the display.
Display:
max. 5-digit number, including unit (e.g. 200 mm)
!
Note!
2 traverses cannot be used if the sensor distance is <180 mm.
Functional description CONFIG. CHANNEL