EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow P 500 - Page 11

Endress+Hauser Proline Prosonic Flow P 500
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prosonic Flow P 500
Endress+Hauser 11
Measuring pipe wall thickness [mm (in)]
Kinematic viscosity cSt [mm
2
/s]
0 < v ≤ 10 10 < v ≤ 100 100 < v ≤ 1000
Converter frequency (sensor version/number of traverses)
1)
> 4.2 to 5.9 (0.17 to 0.23) 1 MHz (C-100 / 2) 1 MHz (C-100 / 1) 0.3 MHz (C-030 / 2)
> 5.9 (0.23) Selection according to table: "Measuring pipe material: steel, cast iron > 5.9 mm (0.23 in)"
1) Table shows a typical selection: In critical cases (large pipe diameter, liner, gas or solid inclusions) the optimum sensor type may differ from these
recommendations.
Measuring pipe material: Steel, cast iron with wall thicknesses > 5.9 mm (0.23 in)
Nominal diameter [mm (")]
Kinematic viscosity cSt [mm
2
/s]
0 < v ≤ 10 10 < v ≤ 100 100 < v ≤ 1000
Converter frequency (sensor version/number of traverses)
1)
15 to 50 (¹⁄₂ to 2) 5 MHz (C-500)
> 50 to 300 (2 to 12) 2 MHz (C-200) 1 MHz (C-100) 1 MHz (C-100)
> 300 to 1 000 (12 to 40) 1 MHz (C-100) 0.3 MHz (C-030) 0.3 MHz (C-030)
> 1 000 to 4 000 (40 to 160) 0.3 MHz (C-030)
1) Table shows a typical selection: In critical cases (large pipe diameter, liner, gas or solid inclusions) the optimum sensor type may differ from these
recommendations.
Measuring pipe material: plastic
Nominal diameter [mm (")]
Kinematic viscosity cSt [mm
2
/s]
0 < v ≤ 10 10 < v ≤ 100 100 < v ≤ 1000
Converter frequency (sensor version/number of traverses)
1)
15 to 50 (¹⁄₂ to 2) 5 MHz (C-500 / 2) 5 MHz (C-500 / 2) 5 MHz (C-500 / 2)
> 50 to 80 (2 to 3) 2 MHz (C-200 / 2) 1 MHz (C-100 / 2) 0.3 MHz (C-030 / 2)
> 80 to 150 (3 to 6) 1 MHz (C-100 / 2) 1 MHz (C-100 / 2) 0.3 MHz (C-030 / 2)
> 150 to 200 (6 to 8) 1 MHz (C-100 / 2) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 2)
> 200 to 300 (8 to 12) 1 MHz (C-100 / 2) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 2)
> 300 to 400 (12 to 16) 1 MHz (C-100 / 1) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 1)
> 400 to 500 (16 to 20) 1 MHz (C-100 / 1) 0.3 MHz (C-030 / 1) 0.3 MHz (C-030 / 1)
> 500 to 1 000 (20 to 40) 0.3 MHz (C-030 / 1) 0.3 MHz (C-030 / 1)
> 1 000 to 4 000 (40 to 160) 0.3 MHz (C-030 / 1)
1) Table shows a typical selection: In critical cases (large pipe diameter, liner, gas or solid inclusions) the optimum sensor type may differ from these
recommendations.
Measuring pipe material: glass-fiber reinforced plastic
Nominal diameter [mm (")]
Kinematic viscosity cSt [mm
2
/s]
0 < v ≤ 10 10 < v ≤ 100 100 < v ≤ 1000
Converter frequency (sensor version/number of traverses)
1)
15 to 50 (¹⁄₂ to 2) 5 MHz (C-500 / 2) 5 MHz (C-500 / 2) 5 MHz (C-500 / 2)
> 50 to 80 (2 to 3) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 1)
> 80 to 150 (3 to 6) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 1) 0.3 MHz (C-030 / 1)
> 150 to 400 (6 to 16) 0.3 MHz (C-030 / 2) 0.3 MHz (C-030 / 1)
> 400 to 500 (16 to 20) 0.3 MHz (C-030 / 1)

Table of Contents

Other manuals for Endress+Hauser Proline Prosonic Flow P 500

Related product manuals