Proline Prowirl 72 FOUNDATION Fieldbus 11 Operation via FOUNDATION Fieldbus
Endress + Hauser 83
Write protection process alarm
If the write protection is disabled (Page 35), the alarm priority specified in the WRITE_PRI
parameter is checked before the status change is relayed to the fieldbus host system. The alarm
priority specifies the behavior in the event if an active write protection alarm WRITE_ALM.
!
Note!
If the option of a process alarm was not activated in the ACK_OPTION parameter, this process
alarm must only be acknowledged in the BLOCK_ALM parameter.
The ALARM_SUM parameter shows the current status of all the process alarms.
11.2.5 Resource Block parameters
The following table shows all the Endress+Hauser-specific parameters of the Resource Block.
Resource Block (device block) / base index 400
Parameter Write access for
operating mode
(MODE_BLK)
Description
Serial Number Read only The serial number of the sensor appears on the display
Sensor -
Type
Read only The sensor type (e.g. Prowirl F) appears on the display.
Sensor -
Serial Number DSC Sensor
Read only The serial number of the DSC sensor appears on the display
Amplifier -
HW Revision No.
Read only The hardware revision number of the amplifier appears on the
display
Amplifier -
HW Identification
Read only The hardware identification number of the amplifier appears on
the display
Amplifier -
SW Revision No.
Read only The software revision number of the amplifier appears on the
display
Amplifier -
SW Identification
Read only The software identification number of the amplifier appears on
the display
Amplifier -
Production No.
Read only The production number of the amplifier appears on the display.
I/O Module -
HW Revision No.
Read only The hardware revision number of the I/O module appears on
the display
I/O Module -
HW Identification
Read only The hardware identification number of the I/O module appears
on the display
I/O Module -
SW Revision No.
Read only The software revision number of the I/O module appears on the
display
I/O Module -
SW Identification
Read only The software identification number of the I/O module appears
on the display
I/O Module -
Production No.
Read only The production number of the I/O module appears on the
display