Enterasys S-Series S8 Chassis Hardware Installation Guide 2-1
2
Installation Requirements and Guidelines
Thischapterdescribesthefollowing:
Site Guidelines
YoumustfollowtheguidelineslistedbelowwhenasiteisselectedfortheS8chassis.Ifyoudonot
followtheguidelines,unsatisfactorynetworkperformancemayresult.
•YoumustinstallanS8chassis,withorwithoutaPoEsubsystem,inarestrictedaccesslocation.
•ToinstalltheS8chassisas
afreestandingunitonashelvingunit,theshelfmustbeableto
support113.4kilograms(250pounds)ofstaticweight.
•IfyouaremidmountingtheS8chassis,youmustbolttheracktothefloororensurethatthe
rackissupportedinsuchawaythatthemid
mountedS8chassisdoesnotcreatetipping
hazard.
•ToinstalltheS8chassisasarackmountedunit,caremustbetakentoensurethattherack
usedwillsupporttheunitandthattherackremainsstab le.
•Toallowproperairflowandcoolingwithintherack,ensurethe f ollowing:
–Ifmultipleproductsareinstalledintherack,therackmustcontainproductswithsimilar
airflow.
–Theremustbe5.08centimeters(2 inches)ofclearancebehindtheS8chassisandoneither
sideoftheS8chassis.
•IfyouareinstallinganS8chassisatthebottomofanenclosedrack,
leaveatleast5.08
centimeters(2 inches)betweentheflooroftherackandtheS8chassistoensureproperair
flowandcooling;otherwise,youriskthemodulesoverheating.
For more information about: Refer to page...
Site Guidelines 2-1
Precautions 2-2
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.