Electrical characteristics
Symbol
Parameter
Conditions
Min
Max
Units
V
I
Nominal Input Voltage
8,4
36
V
V
I-Load-dump
Max Input Transient
Voltage Level
(Note 1) 123 V
V
I-max
Max Continuous Input
Voltage Level
(Note 2) -20 70 V
V
I-ovp
Overvoltage Threshold
Level
typ. 37 V
V
I-uvp
Undervoltage Threshold
Level
typ. 8 V
Supply voltage monitoring
V
I-range
Nominal Input Voltage
measuring range
0 36 V
Note 1: Load dump protection according to ISO7636-2: 2004 pulse 5, Us=+123 V
Note 2: Limited functionality when the voltage is higher than the nominal. If the voltage is less
than 7,7 V, the unit is in non-operational state.