Technical Manual &
Cabling Instructions
Page 50 / MAN000596
Approvals and Safety
Epec Oy reserves all rights for improvements without prior notice
Epec Oy
Tiedekatu 6
FIN-60320 Seinäjoki
Postal address
PL/P.O.Box 194
FIN-60101 Seinäjoki,
Finland
Phone
+358-(0)20-7608 111
Fax
+358-(0)20-7608 110
Internet
www.epec.fi
The following environmental tests have been performed to Epec 6100 and 6107 units (with
WLAN option):
Temperature
Test
Temperature
Duration/
Exposure time
Remarks
Cold
IEC 60068-2-1 (2007-
03),Test Ad
-30 °C 16 h
1 °C/min
Dry heat
IEC 60068-2-2 (2007-
07),Test Bb
+60 °C 16 h
1 °C/min
Change of
temperature IEC
60068-2-14 (2009-
01),
Test Na
-40 °C/+60 °C 3 h
change time between
extreme temperatures 1-
2 min
2 test cycles
Mechanical resis
tance
Test
Duration and direction
Remark
Shock test IEC
60068-2-27 (2008-
02)
Test Ea
pulse duration 6 ms
500 impulses in six
directions
half sine pulse shape
peak acceleration 500 m/s
2
Vibration, random
IEC 60068-2-64
(2008-04),Test Fh
test duration 60 min in
every three test
direction
ASD-level 5 m
2
/s
3
, 10 … 200
Hz
ASD-level 1,0 m
2
/s
3
, 200 … 500
Hz
total spectral acceleration 3,54
grms
Corrosion
Test
Temperature
Duration
Concentration
Salt spray test
ISO 9227
+35 °C 24 h 5 % NaCl
Tightness tests
Test
Duration and procedure Remark
Dust test for IP6X
according to IEC
60529
exposed to the free
settling dust for 3
hours
underpressure during
the test 2 kPa
flow rate of the air 0,4
l/min
no deposit of dust noticed
inside
complies with the requirements
stated for the protection class
IP6X