Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W Revision C
ADJUSTMENT      Adjustment without Using Adjustment Program 239
Confidential
 Checking the result of PG adjustment
1.
Move the carriage to the center of the platen, and place one of the 1.1 mm thickness 
gauges aligning the left edge with the third rib from the left end of the Front Paper 
Guide to the fifth rib. Then place the other 1.1 mm thickness gauge aligning the right 
edge with the second rib from the right end of the Front Paper Guide to the fifth rib. 
( Fig.  5-41 )
Figure 5-41.  Setting the thickness gauge
2. Pull the Timing Belt to move the carriage to both ends and confirm the carriage 
does not touch the gauges.
3. If the carriage comes in contact with a gauge, perform the adjustment again.
4. Move the carriage to the center of the platen, and place 1.3 mm thickness gauges 
on the same position in step1 (instead of 1.15mm ones).
5. Pull the Timing Belt to move the carriage to both ends and confirm the carriage 
comes in contact with the gauges.
6. If the carriage does not touch the gauges, perform the adjustment again.
Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson 
Artisan 700/Epson Stylus Photo PX700W/TX700W have five PG 
pre-settings using the APG mechanism. Use the minimum PG 
setting (PG
 –: 1.2mm) to carry out this checking. See Figure. 5-36.
Gauge (1.15 or 1.3mm) placement
Right side
Gauge (1.15 or 1.3mm) placement
Left side