The message "Not supported" is displayed.
Check Remedy
Is the image signal format setting correct?
Only when projecting images from a video source
Change the setting according to the signal for the connected equipment. s Signal Menu - Video Signal p.75
Do the image signal resolution and refresh rate correspond to the
mode?
Only when projecting computer images
See the documentation supplied with the computer for how to change the image signal resolution and refresh rate output
from the computer. s "List of Supported Resolutions" p.120
The message "No Signal" is displayed.
Check Remedy
Are the cables connected correctly? Check that all the cables required for projection are securely connected. s Quick Start Guide
Is the correct input port selected? Change the image by pressing the [Source Search] button on the remote control or the control panel. s p.21
Is the power of the connected computer or video equipment turned
on?
Turn the power on for the equipment.
Are the image signals being output to the projector?
Only when projecting images from a laptop computer or a computer
with a built-in LCD screen
If the image signals are only being output to the computer's LCD monitor or accessory monitor, change the output so
that the image signals are also output externally. For some computer models, when the image signals are output
externally, they no longer appear on the LCD monitor or accessory monitor.
s
Computer's documentation, under a
title such as "External output" or "Connecting an external monitor"
If the connection is made while the power of the projector or computer is already turned on, the function [Fn] key that
changes the computer's image signal to external output may not work. Turn the power for the computer and the
projector off and then back on again.
Images are fuzzy or out of focus
Check Remedy
Is the focus adjusted correctly? Adjust the focus with the focus lever. s Quick Start Guide
Is the projector at the correct distance? Is it projecting outside of the recommended projection distance range?
Setup within the recommended range. s p.118
Is the Keystone adjustment value large? Lower the projection angle to reduce the amount of keystone correction. s Quick Start Guide
Problem Solving