DISASSEMBLY/ASSEMBLY Disassembling Printer Mechanism 94
Be sure to install the CR Motor so that the groove on it faces
downward.
Figure 4-55. Installing CR Motor
Tighten the screws in the order given in Figure 4-54.
Make sure that there is no gap between the CR Motor and the
Main Frame.
After replacing the CR Motor, be sure to perform the required
adjustment. See
Chapter 5 “ ADJUSTMENT” (p.107)