EasyManua.ls Logo

Epson Stylus C110 - PF Scale; PF Motor

Epson Stylus C110
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus C110/C120/D120 Revision B
DISASSEMBLY/ASSEMBLY Disassembling Printer Mechanism 91
4.5.9 PF Scale
Part/Unit that should be removed before removing PF Scale
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor
Removal Procedure
1. Peel of the PF Scale that is secured with the double-sided tape (x1) from the Spur
Gear 32.4.
Figure 4-47. Removing PF Scale
4.5.10 PF Motor
Part/Unit that should be removed before removing PF Motor
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor/PF Scale
Removal Procedure
1. Release the PF Motor connector cable from the notches (x2) of the Base Frame.
Figure 4-48. Removing PF Motor (1)
2. Remove the Grounding Spring from the PF Motor.
3. Remove the screws (x3) that secure the PF Motor, and remove it.
Figure 4-49. Removing PF Motor (2)
C A U T I O N
Pay attention to the following instructions.
Do not touch the PF Scale with bare hand.
Do not damage the PF Scale.
Spur Gear 32.4
PF Scale
Double-sided Tape
Notch
PF Motor Connector Cable
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
Grounding Spring
PF Motor
Guide Pin and Positioning Hole
1
2
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
3

Table of Contents

Other manuals for Epson Stylus C110

Related product manuals