EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Disassembly & Assembly Disassembly Procedure 250
11. Remove the two screws that secure the CUTTER SOLENOID ASSY. and remove
it.
Two C.P.S.(S-P2) M2.6 x 6 screws
Figure 4-72. Removing the CUTTER SOLENOID ASSY.
A D J U S T M E N T
R E Q U I R E D
Whenever the CUTTER SOLENOID ASSY. is reinstalled or
replaced, the corresponding adjustment must be carried out. See
Chapter 5 on page 292.
C.P.S.(S-P2) 2.6x6
CUTTER
SOLENOID ASSY.