Disassembly & Assembly Disassembly Procedure 280
8. Release the harness of the I/C LEVER SENSOR L from the three hooked tabs of
the HARNESS/TUBE STOPPER and pull out the harness.
9. Pull out the TUBE, PRESSURIZING from the HOLDER ASSY., IC, LEFT, and
release it from the three retaining clips of the HARNESS/TUBE STOPPER.
Figure 4-128. Releasing the I/C LEVER SENSOR L Harness and the TUBE,
PRESSURIZING
Route the harness of the I/C LEVER SENSOR L winding one turn
of it around the hooked tab of the HARNESS/TUBE STOPPER.
See Figure 4-128.
Make sure that the joint of the TUBE, PRESSURIZING is
located at the retaining clip as shown in the figure below.
Figure 4-127. Routing the TUBE, PRESSURIZING
Insert the TUBE, PRESSURIZING all the way.
Joint
Retaining clip
TUBE, PRESSURIZING
8: Hooked tabs
8: Hooked tabs
9: Hooked tabs
I/C LEVER SENSOR L
Harness
HARNESS/TUBE
STOPPER
Routing the I/C LEVER
SENSOR L Harness