EasyManua.ls Logo

Epson TM-T88VI - When a Serial Interface Is Connected

Epson TM-T88VI
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
When a Serial Interface is Connected
DIP Switch Bank 1
Transmission Speed (DIP Switches 1-7/1-8)
bps: bits per second
* The default value of transmission speed set with software settings is 38400 bps. (See
"Software Settings" on
page 60
.)
SW Function ON OFF
Default
setting
1-1 Data reception error Ignored Prints “?” OFF
1-2 Receive buffer capacity 45 bytes 4 KB OFF
1-3 Handshaking XON/XOFF DTR/DSR OFF
1-4 Word length 7 bits 8 bits OFF
1-5 Parity check Yes No OFF
1-6 Parity selection Even Odd OFF
1-7
Baud rate selections
See the
" Transmission Speed (DIP Switches 1-7/1-
8)"
table below.
ON
1-8 OFF
For DIP switch 1-2 (Receive buffer capacity), see also DIP switch 2-5 (Sets the release condition of
the receive buffer BUSY state.)
Transmission speed (bps: bits per second) SW 1-7 SW 1-8
Depends on the software setting mode settings.* ON ON
4800 OFF ON
9600 (default) ON OFF
19200 OFF OFF
Depending on print conditions, such as print duty, print head temperature, and data transmission
speed, print speed is automatically adjusted, which can cause white lines due to intermittent
print (the motor sometimes stops). To avoid this, set the transmission speed higher or keep the
print speed constant by setting it lower.