58
When Another Interface is Connected
DIP Switch Bank 1
* This is enabled only when the communication status for the USB interface is set in the vendor definition class,
and the system configurations under which USB drivers support USB power saving functions.
DIP Switch Bank 2
SW Function ON OFF
Default
setting
1-1 Auto line feed Always enabled Always disabled OFF
1-2 Receive buffer capacity 45 bytes 4 KB OFF
1-3
Selects paper sensors to output
paper-end signals (default value of a
command)
Disabled
Roll paper end sensor
enabled, roll paper near-
end sensor enabled
OFF
1-4 Error signal output Disabled Enabled OFF
1-5
1-7
Undefined — OFF
1-8 USB power saving function Disabled Enabled* OFF
SW Function ON OFF
Default
setting
2-1 Handshaking (BUSY condition) Receive buffer full
Offline
Receive buffer full
OFF
2-2 Reserved (Do not change setting) Fixed to OFF OFF
2-3
2-4
Selects print density
See "Selecting the Print Density (DIP Switches 2-3/
2-4)" on page 59
.
OFF
2-5
Sets the release condition of the
receive buffer BUSY state. (This
function is effective when DIP Switch
1-2 is set to off.)
Releases the BUSY state
when the remaining
capacity of the receive
buffer reaches 138 bytes.
Releases the BUSY state
when the remaining
capacity of the receive
buffer reaches 256 bytes.
OFF
2-6
2-7
Reserved (Do not change settings) Fixed to OFF OFF
2-8
Reserved (Do not change settings) Fixed to OFF OFF
IF pin 31 reset signal Fixed to ON ON
For DIP Switch 2-1 (BUSY condition), see also
"Selecting the BUSY Status" on page 59.