EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
F
TM-U295/U295P
Specification
(STANDARD)
23 22
Table 3.3.2 Transmission Speed
DIP Switch 1-8 DIP Switch 1-7 Transmission Speed
ON ON 1200 bps
ON OFF 2400 bps
OFF ON 4800 bps
OFF OFF 9600 bps
NOTES: 1 The DIP switch settings, except for Pin 6 : Reset Signal (1-9) and Pin 25 : Reset Signal
(1-10), are effective only when the power is turned on. Therefore, once the power is has
been turned on, changing the settings is ineffective.
2 If the DIP switches 1-9 or 1-10 are set to ON while the power is supplied, the printer may
be reset depending on the state of the signal lines, so do not change the DIP switch
settings while power is supplied.
2) For parallel interface model
Table 3.3.3 DIP Switch 1
DIP Switch
1
Function ON OFF
1 Automatic line feed Always enable Always disable
2 Receive buffer capacity Data buffer 35 bytes Data buffer 512 bytes
3 Undefined
4 Undefined
5 Undefined
6 Undefined
7 Undefined
8 Undefined
9 Undefined
10 Internal use Fixed to ON
NOTES: 1 The DIP switch settings are effective only when the power is turned on. Therefore, once
the power has been turned on, changing the settings is ineffective.