EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
127 (200)
Change the 1
st
entry in this column to the correct IP address, select the 1
st
entry, then left-click the 1
st
entry & drag down to the bottom of the column
to highlight all entries. Right click & select “Replicate cell”, all entries in the
Ne Name” column will now be set to the required OOB IP Address.
d. Scroll right to the “Default GW IP Addr” column
e. The Default GW IP Addr” column must now be filled in with the Default
GW addresses for all ten POTS cards slots 3 to 21. (Even if only one POTS
card is physically installed.)
Explanation: The Def GW IP Addresses are determined from the POTS
cards IP Addresses, if the POTS card IP Addr = a . b . c . d
So the Def GW IP Addr becomes = a . b . c+1 . 254
In this example the following POTS card Def GW IP Addresses have been
used:-
POTS
Slot No.
Profile
No.
POTS Card IP
Addr
POTS Card
Def GW Addr
3 2 10.67.130.102 10.67.131.254
5 3 10.67.132.102 10.67.133.254
7 4 10.67.134.102 10.67.135.254
9 5 10.67.136.102 10.67.137.254
11 6 10.67.138.102 10.67.139.254
13 7 10.67.140.102 10.67.141.254
15 8 10.67.142.102 10.67.143.254
17 9 10.67.144.102 10.67.145.254
19 10 10.67.146.102 10.67.147.254
21 11 10.67.148.102 10.67.149.254
Refer to the following figure.