EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
132 (200)
e. Select the “CLI Profile” field, and set it to “1: UK” from the drop-down list.
f. Check that the “ToIP Profile” field is set to “1”.
g. In the RTP Profile” field select the appropriate profile number for the
relevant POTS card slot position, refer to the following table. It is very
important to set the correct value.
Note: Do NOT select RTP Profile of “1”, this a default profile.
h. In the “RTP Local IP Address” field, enter the appropriate IP Address for
the relevant POTS card slot position. This address is unique for the slot
position and is also site specific. Refer to the “CWA Voice Card
Deployment” spreadsheet for the site being commissioned.
i. In the “Metering Level (mV)” field change the entry from 0 to “200” (use
the up arrow).
j. Leave all of the other settings at their defaults.
k. All of the above settings have been made for Line 1, the same settings
have to be replicated for Line 2 through to and including Line 64. This can
be done quickly by pressing and holding down the Shift key whilst clicking
on the Line 64 button. All of the ports will turn red.
POTS Slot RTP Profile
3 2
5 3
7 4
9 5
11 6
13 7
15 8
17 9
19 10
21 11