EasyManua.ls Logo

Ericsson EDA 2530 - Page 166

Ericsson EDA 2530
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
166 (200)
k. Click on the Apply to Selection button.
l. Wait until the ‘Applying the configuration to the selected lines, please wait.’
message disappears.
m. Select SHDSL Line1.
n. Wait until the Address: shows Slot (as selected), Card Type: SHDSLx32,
Line: (as selected) then check that the Configuration Profile is set to SHDSL
Profile 1.
o. Click on the next SHDSL Line to be checked.
p. Repeat steps (n.) to (o.) until all 32 lines have been checked.
q. When all 32 lines have been checked on the 32 x SHDSL card click on the
Close button to close the window.
9.2.1.3 Enable all 32 SHDSL Lines
The SHDSL Lines must now be enabled, perform the following steps:-
a. From the LCT main screen select the path;-
Configuration xDSL Line Activation

Table of Contents