EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
167 (200)
b. Set the Slot: box to the SHDSL card slot to be re-enabled.
c. Select the ~ Enable radio button.
d. Click on the GO button. Wait for all 32 lines to be enabled.
e. Check the result is Found (Configured); 32 Updated: 32 Failed: 00.
If there are any failures click on the View Error Log button and read the
display. Any disabled lines will have to be enabled manually.
f. Select the ~ Check radio button.
g. Click on the GO button. Wait for all 32 lines to be checked.
h. Check the result is Found (Configured); 32 Enabled: 32 Disabled: 00.
If there are any lines Disabled, click on the View Error Log button and read
the display. Any disabled lines will have to be enabled manually.
9.2.1.4 Enable or Disable an SHDSL Line Manually (For Reference Only)
This Section is only required if an SHDSL line needs to be manually Enabled or
Disabled.
a. Place the cursor on the <32 x SHDSL unit > to be configured.
b. Right click on the unit and select Lines from the menu.