2.4.4.2 64 x POTS/VoIP Unit (02HAT00198AAM)
EDA 2530 subrack:- The 64 x POTS/VoIP Unit should be fitted in the Odd Slots
Only, from slots 3 to slot 21 with up to a maximum of ten cards, providing a
maximum of 640 lines. Each 64 x POTS/VoIP card requires its relevant Connection
Unit to be fitted above the 64 x POTS/VoIP card.
Note: When the combination of 64 x ADSL2+ and 64 x POTS/VoIP Units are
used, the Connection Unit required is the 64 x COMBI I/F + IN/Out POTS + TAM
ETSI Connection Unit (02HAT00282AAQ).
Figure 2.7 – 64 x POTS/VoIP Unit
The card front is equipped with 3 LED’s whose functions are as follows.
T (yellow) On unit normal activity
Off unit has a protecting role
Blinking configuration is being changed.
PWR (green) On unit is powered up
ALARM (red) Off normal activity
On internal alarm.
Blinking external alarm
T
PWR
RS232
02HAT 00198 AAM
POTS/VoIP x 64
T
PWR
RS232
02HAT 00198 AAM
POTS/VoIP x 64